Strona 1 - Home Integrated System

Home Integrated System Wireless Security & Home Automation System Installation & Operating Manual

Strona 2 - CONTENTS

8Inside View of Smart Home Box TESTING THE SMART HOME BOX & REMOTE CONTROL 1. Press , ,

Strona 3 - KIT CONTENTS

9The PIR Detector adopts a 1/2 AA size 3.6V Lithium battery which under normal conditions will have typical life in excess of 4 years. Whe

Strona 4 - INTRODUCTION AND OVERVIEW

102. Carefully drill out the required mounting holes in the rear cover using 3mm drill according to whether the unit is being mounted in a cor

Strona 5

11 Set the required sensitivity detection using DIP2 of SW2 as follows: ON high sensitivity detection OFF low sensitivity detection Note:

Strona 6 - HOME AUTOMATION

121. Press , , to put the system into Test mode. ‘WALK TEST’ will be displayed. 2.

Strona 7 - WIREFREE ALARM SYSTEM

13 2. Fit the 3.6V Lithium battery supplied, with the negative (-) towards the battery spring. 3. Mount the Detecto

Strona 8 - SMART HOME BOX

14b. Select ‘3-1 Wireless Sensor Zone’ and press . c. ‘Input (01-32) Sensor Zone’ and press . d. An indication of ‘:1 Learning

Strona 9 - MOUNTING THE SMART HOME BOX

15status of the plug-in light fixtures or home appliances without controlling via Smart Home Box.LEARNING ID CODE In order to communicate with the

Strona 10 - PASSIVE INFRARED DETECTORS

161. Press , , to put the system into Test mode. ‘WALK TEST’ will be displayed. 2. Press

Strona 11 - INSTALLING THE PIR DETECTORS

17TESTING THE SYSTEM INITIAL TESTING As the system is initially installed it is recommended that each device is tested in turn as it is instal

Strona 12 - SETTING THE PIR DETECTORS

CONTENTSKIT CONTENTS 1 INTRODUCTION AND OVERVIEW 2 Multiple Users 2 System Arming 2

Strona 13 - TESTING THE PIR DETECTORS

18Press to exit Walk Test and return to the top level Test Mode menu. RF ENVIRONMENT TEST Scroll through the top level Test Mode

Strona 14 - DETECTOR(S)

19Night Alarm ON Key Tone ON Back Light 20s Error Beep 30s Auto Report Function 12h RF Jamming Detection OFF Alarm Relay On Until Disarm Zone L

Strona 15 - SETTING THE MAGNETIC CONTACT

20Backup & Restore Backup Today’s DD/MM/YY Restore Not Programmed RESETAfter carrying out the following steps, the Smart Home Box will not re

Strona 16 - ON/OFF RECEIVER

21PROGRAMMING INSTRUCTIONS With the system in Disarm Mode. Press , ,

Strona 17 - WALL SWITCH

22display once the system is armed/disarmed by the particular user. The maximum memorized capacity for each user name is 15 digits. Scroll thr

Strona 18 - EXTERNAL CONNECTIONS

Code Learning Pressing , or button on the remote control will enable the Smart Home Box to learn the IDcode. Scroll throu

Strona 19 - TESTING THE SYSTEM

24HOME BOX SETUP 2. Home Box Setup PROGRAM MODE C

Strona 20 - DEFAULT SETTINGS

25Scroll through the top level programming menu until ‘2. HOME BOX SETUP’ is displayed and press . Note: After completing the system setup

Strona 21 - GSM Gateway SMS Remote

26KEY TONE This feature, if enabled, allows the Smart Home Box to sound a tone each time the keypad is pressed. Default setting: ON Scroll through

Strona 22

27ALARM RELAY This setting controls the operation period for the NO/NC hardwired output relay contacts following an alarm condition being

Strona 23 - PROGRAMMING INSTRUCTIONS

1KIT CONTENTS The Alarm System should contain the following components. For HIS20S 1 x Smart Home Box 1 x Wireless Key 1 x PIR Detector 1 x Remote Con

Strona 24

28 Press to enable the Entry-delay beep, or Press to disable the Entry-delay beep. DATE This feature is for setting o

Strona 25

29SECURITY SENSOR ZONE SETUP (for Wire Sensor Zone) (for Wireless Sensor Zone) :6 Night A

Strona 26 - HOME BOX SETUP

30This section is for setting of adding and categorizing of security devices (e.g. PIR detector). Scroll through the programming menu until ‘3

Strona 27

31- used to provide 24-hour monitoring of any Fire/Smoke detectors fitted to the system. Activation of any detector will immediately ini

Strona 28

32Press to disable the Magnetic Contact Detector. AUTO REPORT This feature, if enabled, allows the detector to give feedback to t

Strona 29

33PHONE/LINE SETUP PROGRAM MODECode: 4-4 Dial Method Setup: xxxxDTMFPULSE4-1 Voice DialSetup 4. Phone/Lin

Strona 30

34Scroll through the programming menu until ‘4-1. Voice Dial Setup’ is displayed and press . Note: After completing the Phone/Line Set

Strona 31 - SECURITY SENSOR ZONE SETUP

35Press to delete the character under the cursor. Press and hold to erase the entire phone number. UNIT ID NUMBER This hel

Strona 32

36 Note: If you find Monitor Center is not working properly, please check the telephone no. and Unit ID no. you ente

Strona 33

37NUMBER OF DIALING CALL This facility controls the number of dialing call via the connected telephone line. Default setting: one call Scroll thr

Strona 34

2INTRODUCTION AND OVERVIEW MULTIPLE USERS The system allows for up to 7 Users and an Administrator to be configured. This allows the

Strona 35 - PHONE/LINE SETUP

38NOTIFICATION SETUP PROGRAM MODECode: 5. Notification Setup 5-1 Set TEL No. Input Number Delete Inpu

Strona 36

39NOTIFICATION SETUP Scroll through the programming menu until ‘5.Notification Setup’ is displayed and press . Note: After completi

Strona 37

40 Enter the required number (1-6). Press to save and exit, or Press to exit without saving. DIAL ROUND This sets the maxim

Strona 38

41GREEN HOME SETUP PROGRAM MODE Code: 6. Green Home6-1 Green Control 6-2 Green Remote/Sensor Input (

Strona 39

42Green Home setting is designed specially for home automation types of devices, i.e. device with 433 MHz radio frequency. Scroll through t

Strona 40 - NOTIFICATION SETUP

43Scroll through available options, (Curtain Switch, Dimmer and Switch Device ) until the required model type is displayed and then Press

Strona 41

44 Press to retain the device. RECORD SCENE VOICE This voice record is set for scene, event and schedule. Scroll through the menu

Strona 42

45 ENHANCE SETUP PROGRAM MODE Code:7. Enhance7-1 Enhance Device Input (01-12) E Device NO. :1 Model Type

Strona 43 - GREEN HOME SETUP

46Enhance setting is designed specially for transceiver type of devices, i.e. device with 868 MHz radio frequency. Scroll through t

Strona 44

47BACKUP & RESTORE Scroll through the programming menu until ‘8.BACKUP & RESTORE’ is displayed and press . Use

Strona 45

3QUICK SET The system may be fully armed in 5 seconds using the quick set facility, overriding the programmed exit-delay. This is useful for setting t

Strona 46

48OPERATING INSTRUCTIONS When leaving the premises, the system must be Armed. However, before doing so, check that all windows are closed and locked

Strona 47 - ENHANCE SETUP

49Password, and then the ‘Enter’ button. If User password is correct, an indication of ‘Night Arm’ will be shown on the LCD screen:

Strona 48

50Use (On), (Off), (Start) and (Stop) buttons to control the green control related actions. ScenePress to enter

Strona 49 - BACKUP & RESTORE

51Setting Sequence: Press -> plays “I will watch over the house!” -> system enters fully arm mode -> PIR Detector sets to ON whi

Strona 50 - OPERATING INSTRUCTIONS

52Press to initiate ARM. Press to initiate Partial Arm. Press to initiate H

Strona 51

53removed). Wall Switch Under low battery conditions, when the button is pressed, the LED will flash. Under normal battery conditions the LED w

Strona 52 - On steadily Flash Off

54ALARM RECORD Complete the following information during installation for future reference when adding to your system and to assist Trouble Shooting.

Strona 53 - REMOTE SYSTEM CONTROL

55Zone Detector Type(s) Location Type Chime Night Arm Partial Arm 33 34 35 36 You may make a note of your U

Strona 54 - BATTERY MONITORING

56ALARM LEVEL To help you distinguish the difference among Level Panic, Level 1, Level 2 and Level 3, their definition read as follows: Level Panic: A

Strona 55 - MAINTENANCE

57Gateway will send SMS message, error beep will generate at regular intervals and this specific event will be recorded in the event log as well. Leve

Strona 56 - ALARM RECORD

4a 5 minute interval, this will also generate a Full Alarm condition.The jamming detection features in the Smart Home Box and Solar Siren operate inde

Strona 57

58TROUBLESHOOTINGSmart Home Box not working – Power LED OFF or flashing1. Mains power failure – check if other electrical circuits are operable. 2.

Strona 58 - ALARM LEVEL

59LED on remote control not illuminating, or is dim when unit is operated1. Ensure battery is connected with correct polarity2. Ensure batter

Strona 60 - TROUBLESHOOTING

5PLANNING AND EXTENDING YOUR WIREFREE ALARM SYSTEM The following example shows a typical property incorporating the suggested positions for

Strona 61 - PROTOCOL

6REMOTE CONTROL UNIT A LED indicator F Key Chain Ring B Fully Arm/Holiday Arm G Battery Cover C Night Arm/Partial Arm H Negative

Strona 62

7connecting to a telephone master or secondary outlet.7. Do not locate the Smart Home Box closer than 1m to any large metallic object, (e.g. mi